<img src="Images/Pipemove1.gif" width=387 height=39 border=0>
 
 
 

"SHAKTHIMAN SUPER" is available in the latest Indian Standard specifications. The Bureau of Indian Standards has released the Third Revision of the standard, IS: 4985/2000, for Unplasticized Polyvinyl Chloride Pipes for Potable Water Supplies. Three new material tests for determining the Sulphated Ash Content, Vicat Softening Temperature and Density are incorporated in IS: 4985/2000. The revision of the standard has made it more in line with the ISO: 4422/92 standards on UPVC pipes. Chloroplast is the first to introduce this Standard in the State.

   
 

Various tests conducted on SHAKTHIMAN SUPER PVC pipes and its conformities are given below:-

   
   
 
Sl No.
Name of Test
Conformity
1
Visual Appearance
Colour light grey.Both inner and outer surfaces shall be smooth
2
Opacity Test
Does not pass more than 0.2% of falling light
3
Effect on Water
Lead, Dialkyl tin C4 and other toxic substances shall be within the prescribed limit.
4
Reversion Test
The change in length shall be ± 5%
5
Vicat Softening Temperature Test
The penetration shall not be more than 1mm at 80 °C
6
Density
1.4 - 1.46
7
Sulphated Ash Content Test
Ash content shall be below 11%
8
Internal Hydrostatic pressure test (Acceptance).
The pipe shall not burst at the test pressure
9
Internal Hydrostatic pressure test (Type)
The pipe shall not burst at the test pressure
10
Resistance to External Blows at 0 0 C
The true impact rate shall be below 10%
   
  The dimensional details of UPVC pipes as per IS: 4985/2000, Table 1, are given below. Pipes are supplied in 5/6 metres length with plain ends or with socket at one end.
   
DIMENSIONS OF UNPLASTICIZED PVC PIPES– AS PER IS: 4985/2000
TABLE 1  (Clauses 7. 1. 1 and 7. 1. 2)
FOR PIPES IN CLASSES 1, 2 & 3
All dimensions in millimeters
Nominal Outside Diameter
Mean Outside Diameter
Outside Diameter At Any Point
Wall Thickness
i
i
i
i
i
Class- (0.25Mpa)
Class-2(0.40 Mpa)
Class-3 (0.60 Mpa)
i
 Min
  Max  
  Min   
  Max  
Avg.   Max.  
  Min   
 Max   
Avg.   Max.  
   Min  
 Max 
Avg Max
Min
Max
20
20.0
20.3
19.5
20.5
.
.
.
.
.
.
. . .
25
25.0
25.3
24.5
25.5
.
.
.
.
.
.
. . .
32
32.0
32.3
31.5
32.5
.
.
.
.
.
.
.
.
.
40
40.0
40.3
39.5
46.5
.
.
.
.
.
.
1.8
1.4
1.8
50
50.0
50.3
49.4
50.6
.
.
.
.
.
.
2.1
1.7
2.1
63
63.0
63.3
62.2
63.8
.
.
.
1.9
1.5
1.9
2.7
2.2
2.7
75
75.0
75.3
74.1
75.9
.
.
.
2.2
1.8
2.2
3.1
2.6
3.1
90
90.0
90.3
88.9
91.1
1.7
1.3
1.7
2.6
2.1
2.6
3.7
3.1
3.7
110
110.0
110.4
108.6
111.4
2.0
1.6
2.0
3.0
2.5
3.0
4.3
3.7
4.3
125
125.0
125.4
123.5
126.5
2.2
1.8
2.2
3.4
2.9
3.4
5.0
4.3
5.0
140
140.0
140.5
138.3
141.7
2.4
2.0
2.4
3.8
3.2
3.8
5.5
4.8
5.5
160
160.0
160.5
158.0
162.0
2.8
2.3
2.8
4.3
3.7
4.3
6.2
5.4
6.2
 
DIMENSIONS OF UNPLASTICIZED PVC PIPES– AS PER IS: 4985/2000
TABLE 1  (Clauses 7. 1. 1 and 7. 1. 2)
FOR PIPES IN CLASSES 4, 5 & 6
All dimensions in millimeters
Nominal Outside Diameter
Mean Outside Diameter
Outside Diameter At Any Point
Wall Thickness
i
i
i
i
i
 
Class-4 (0.80 Mpa)
Class-5(1.00 Mpa)
Class-6 (1.25 Mpa)
i
Min
  Max  
  Min   
  Max  
Avg.   Max.  
  Min   
 Max   
Avg.   Max.  
   Min  
 Max 
Avg Max
Min
Max
20
20.0
20.3
19.5
20.5
.
.
.
1.5
1.1
1.5
1.8
1.4
1.8
25
25.0
25.3
24.5
25.5
1.6
1.2
1.6
1.8
1.4
1.8
2.1
1.7
2.1
32
32.0
32.3
31.5
32.5
1.9
1.5
1.9
2.2
1.8
2.2
2.7
2.2
2.7
40
40.0
40.3
39.5
46.5
2.2
1.8
2.2
2.7
2.2
2.7
3.3
2.8
3.3
50
50.0
50.3
49.4
50.6
2.8
2.3
2.8
3.3
2.8
3.3
4.0
3.4
4.0
63
63.0
63.3
62.2
63.8
3.3
2.8
3.3
4.1
3.5
4.1
5.0
4.3
5.0
75
75.0
75.3
74.1
75.9
4.0
3.4
4.0
4.9
4.2
4.9
5.9
5.1
5.9
90
90.0
90.3
88.9
91.1
4.6
4.0
4.6
5.7
5.0
5.7
7.1
6.1
7.1
110
110.0
110.4
108.6
111.4
5.6
4.9
5.6
7.1
6.1
7.1
8.7
7.5
8.7
125
125.0
125.4
123.5
126.5
6.4
5.6
6.4
8.0
6.9
8.0
9.8
8.5
9.8
140
140.0
140.5
138.3
141.7
7.3
6.3
7.3
8.9
7.7
8.9
11.0
9.5
11.0
160
160.0
160.5
158.0
162.0
8.3
7.2
8.3
10.2
8.8
10.2
12.6
10.9
12.6
 
 
 
  Extra thick plain ended pipes, ideally suited for Plumbing applications in buildings, are available in sizes 20 mm to 50mm as per Table 2 of IS: 4985/2000 specifications. The dimensional details of Plumbing Pipes are given below:-
   
   
DIMENSIONS OF UPVC PLAIN ENDED PIPES FOR PLUMBING IN BUILDINGS
TABLE 2 - AS PER IS: 4985/2000 – (Clause 7. 1. 3)
All dimensions in millimeters
NOMINAL OUTSIDE DIA.
MEAN OUTSIDE DIAMETER
OUTSIDE DIA. AT ANY POINT
WALL THICKNESS
i
Min.
      Max.     
      Min.      
     Max.     .
      Min.      
     Max.     
20
20.0
20.3
19.5
20.5
2.8
3.3
25
25.0
25.3
24.5
25.5
5.9
3.4
32
32.0
32.3
31.5
32.5
3.4
3.9
40
40.0
40.3
39.5
40.5
3.6
4.2
50
50.0
50.3
49.4
50.6
3.7
4.3
 

 



Web design & Software Development : excellone.com